Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.205
Filtrar
1.
Clin Oral Investig ; 28(4): 211, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480601

RESUMO

OBJECTIVES: The objective of this single-use, five-treatment, five-period, cross-over randomized controlled trial (RCT) was to compare the efficacy in dental plaque removal of a new Y-shaped automatic electric toothbrush (Y-brush) compared to a U-shaped automatic electric toothbrush (U-brush), a manual toothbrushing procedure (for 45 and 120 s), and no brushing (negative control). MATERIALS AND METHODS: Eligible participants were volunteer students randomized to the treatments in the five periods of the study. The primary outcome measure was the reduction in full-mouth plaque score (FMPS) after brushing while the secondary outcome variable was a visual analogic scale (VAS) on subjective clean mouth sensation. Mixed models were performed for difference in FMPS and VAS. RESULTS: After brushing procedures, manual toothbrushing (120 s) showed a statistically significant reduction in FMPS than Y-brush (difference 36.9; 95%CI 29.6 to 44.1, p < 0.0001), U-brush (difference 42.3; 95%CI 35.1 to 49.6, p < 0.0001), manual brushing (45 s) (difference 13.8; 95%CI 6.5 to 21.1, p < 0.0001), and No brushing (difference 46.6; 95%CI 39.3 to 53.9, p < 0.0001). Y-brush was significantly more effective than No brushing (difference 9.8; 95%CI 2.5 to 17.0, p = 0.0030), while there was no significant difference compared to U- brush. Similar results were obtained for the differences in the Clean Mouth VAS. CONCLUSIONS: Y-brush was significantly more effective than no brushing (negative control) in removing dental plaque. When compared to manual toothbrushing for both 45 and 120 s, however, Y-brush was less effective in dental plaque removal. CLINICAL RELEVANCE: Modified design of automatic toothbrushing devices could improve plaque reduction, especially in patients with intellectual disabilities or motor difficulties.


Assuntos
Placa Dentária , Succinimidas , Escovação Dentária , Humanos , Nylons , Placa Dentária/terapia , Desenho de Equipamento , Índice de Placa Dentária , Método Simples-Cego , Estudos Cross-Over
2.
BMC Oral Health ; 23(1): 796, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880662

RESUMO

BACKGROUND: Effective dental plaque removal is essential for oral health. Different toothbrush parameters including head-size, filament-diameter and interdent-height and different brushing movements like horizontal, rotating and vertical may affect plaque removal efficacy. The purpose of the study was to examine plaque removal efficacy of different design parameters of manual toothbrushes. METHODS: Eight manual toothbrushes were tested using a validated robot test to examine efficacy of toothbrush on replicated human teeth. Characteristics tested were: (i) head-size, (ii) filament-diameter, (iii) cutting-height, (iv) hardness, (v) interdental-height. Each test ran five times in horizontal, rotating, vertical movements. Simulated Plaque removal was evaluated using automated plaque planimetry: 30 fields/tooth, 13 areas representing buccal, lingual, proximal tooth sites. The Kolmogorov-Smirnov-test was applied to test tooth surface variables for normal distribution of plaque removal values. Parameters were analysed by independent two-sample t-test to assess mean differences. Where null hypothesis of normality was rejected, the Wilcoxon-Mann-Whitney-U-test was used. RESULTS: Plaque removal was significantly better with toothbrush having smaller head-size (compact vs. full-size); smaller filament-diameter (0.12 mm vs. 0.15 mm); larger cutting-height (12 mm vs. 9 mm); softer filaments (0.15 or 0.18 mm vs. 0.23 mm) and greater interdent-height difference (8.5/11 mm vs. 10/11 mm). CONCLUSIONS: Manual brushes allowing filaments free to flex with longer, softer and/or having a difference in filament length overall removed significantly more simulated plaque as compared to more standard flat trim, stiff brushes with shorter, harder bristles and a larger head size. While limited by the in vitro nature of the study design, this indicates that the advances in toothbrush design can further enhance plaque removal.


Assuntos
Anormalidades Múltiplas , Placa Dentária , Dentes Fusionados , Dente , Humanos , Desenho de Equipamento , Índice de Placa Dentária , Escovação Dentária , Placa Dentária/terapia , Método Simples-Cego
3.
Natal; s.n; 20 out. 2023. 26 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1532072

RESUMO

Introdução: As resinas Bulk Fill apresentam uma boa procura pelos profissionais, pois o seu uso diminui o tempo clínico, como também a melhora qualidade das restaurações, porém não possuem atividade antibacteriana, sendo um dos fatores que ainda causam impacto negativo na vida das pessoas. A biomodificação com o xilitol tem o sentido de produzir ação microbiana e com isso aperfeiçoar as suas características clínicas. Objetivo: Avaliar a ação antimicrobiana de uma resina Bulk Fill flow após a inserção do xilitol. Metodologia: A resina Tetric® N-Flow Bulk Fill foi misturada às concentrações de xilitol (0% [Controle], 2,5% e 5% p/p). Amostras cilíndricas (n=5 do grupo controle e n=3 dos demais grupos experimentais) foram confeccionadas em moldes acrílicos de diâmetro de 2mm espessura, fotoativadas por 10s e armazenadas a 37ºC por 24h. Os espécimes foram esterilizados por luz ultravioleta por 20 minutos antes de serem acomodadas em uma placa de 48 poços estéril, sendo adicionado em cada poço 0,5mL de caldo Mueller Hinton. Então, adicionou-se 50µL do inóculo de S. mutans nos poços correspondentes. A placa foi incubada a 37 ± 1 ˚C durante 48 horas. Após o período de incubação, os espécimes foram gentilmente removidos e o crescimento microbiano foi indicado pela adição de 100µL da solução aquosa de resazurina (SigmaAldrich) a 0,01% com a posterior incubação a 37 ± 1 ˚C por duas horas. Micro-organismos viáveis reduzem o corante mudando sua coloração azul para rosa e a CIM foi definida como a menor concentração da substância que inibiu a mudança de coloração da resazurina. Em um poço contendo o grupo controle foi acrescentado clorexidina a 0,12% com o intuito de comparar o resultado gerado dos grupos testes. Resultado: Não houve inibição do crescimento bacteriano nos poços com inóculos que continham S. mutans e corpo de prova de resina acrescida de xilitol. Conclusão: Esse estudo mostrou que o acréscimo de 2,5% e 5% de Xilitol à resina Tetric® N-Flow Bulk Fill não apresentou inibição do crescimento bacteriano (AU).


Introduction: Bulk Fill resins are in good demand among professionals, as their use reduces clinical time and improves the quality of restorations, but they do not have antibacterial activity, which is one of the factors that still hurt people's lives. Biomodification with xylitol aims to improve its clinical characteristics. Objective: To evaluate the antimicrobial action of a Bulk Fill flow resin after inserting xylitol. Methodology: Tetric® N-Flow Bulk Fill resin was mixed with xylitol concentrations (0% [Control], 2.5% and 5% w/w). Cylindrical samples (n=5 from the control group and n=3 from the other groups) were made in acrylic molds with a diameter of 2 mm thick, light-cured for 10 s and stored at 37ºC for 24h. The specimens were sterilized by ultraviolet light for 20 minutes before being placed in a sterile 48-well plate, with 0.5 mL of Mueller Hinton broth added to each well. The plate was incubated at 37 ± 1 ˚C for 48 hours. After the incubation period, the specimens were gently removed, and microbial growth was indicated by adding 100 µL of 0.01% resazurin aqueous solution with subsequent incubation at 37 ± 1 ˚C for two hours. Viable microorganisms reduce the dye, changing its color from blue to pink. The MIC was defined as the lowest concentration of the substance that inhibited the color change of resazurin. In 0.12%, chlorhexidine was added to a well containing the control group to compare the results generated from the test groups. Result: There was no inhibition of bacterial growth in the wells with inocula containing S. mutans and the resin specimen with xylitol added. Conclusion: This study showed that adding 2.5% and 5% Xylitol to the Tetric® N-Flow Bulk Fill resin did not inhibit bacterial growth (AU).


Assuntos
Streptococcus mutans/patogenicidade , Xilitol/efeitos adversos , Resinas Compostas , Antibacterianos/efeitos adversos , Técnicas In Vitro/métodos , Clorexidina/efeitos adversos , Grupos Controle , Placa Dentária/terapia , Restauração Dentária Permanente
4.
J Periodontol ; 94(9): 1122-1132, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37070363

RESUMO

BACKGROUND: Peri-implantitis is a frequent finding. Initial treatment involves non-surgical debridement of the implant surface. Recent studies have found a correlation between titanium (Ti) particle release and peri-implantitis, yet there is a dearth of information regarding the effect of various non-surgical instrumentation on particle release or peri-implantitis resolution. METHODS: Patients with peri-implantitis were recruited for a randomized, blinded, parallel-group clinical trial. The implants were randomized to treatment composed of Ti curettes ("Mech" group) or implant-specific treatment composed of rotary polymer microbrushes ("Imp" group). Ti release in submucosal peri-implant plaque pre- and 8 weeks posttreatment was assessed as the primary outcome. Peri-implant probing depth, bleeding on probing, and suppuration on probing were evaluated and compared between groups. RESULTS: Thirty-four participants completed treatment; 18 were randomized to the Mech group and 16 to the Imp group. The groups were comparable for Ti levels and probing depths at baseline. A trend was noted for 10-fold greater Ti dissolution in the Mech group posttreatment compared to the Imp group (p = 0.069). The Imp group had a significant reduction in probing depth posttreatment (p = 0.006), while the Mech group reduction was not significant. CONCLUSION: Peri-implantitis treated non-surgically with implant-specific instruments (Imp group) had a significantly greater decrease in probing depth versus the Mech treatment group. This improvement was linked with a trend for less Ti release to the peri-implant plaque by the non-abrasive treatment.


Assuntos
Implantes Dentários , Placa Dentária , Peri-Implantite , Humanos , Peri-Implantite/cirurgia , Peri-Implantite/tratamento farmacológico , Titânio/uso terapêutico , Placa Dentária/terapia , Resultado do Tratamento
5.
Can J Dent Hyg ; 57(1): 7-13, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36968802

RESUMO

Background: Supragingival air polishing of teeth effectively removes dental plaque and extrinsic stain on coronal tooth surfaces, but its impact on specific periodontal pathogens in adjacent subgingival biofilms is not known. This study assessed the microbiological effect of supragingival air polishing on the subgingival microbiota of individuals with severe periodontitis. Methods: Supragingival air polishing with a sodium bicarbonatebased powder was performed on 15 adult test subjects, with the nozzle of the air polishing device aimed apically at a 45° angle onto tooth surfaces immediately coronal to the entrance of periodontal pockets. Supragingival prophylaxis paste polishing, using a slow-speed handpiece, was carried out on 13 adult control subjects. Subgingival specimens were collected from a single 5 mm to 7 mm periodontal pocket with bleeding on probing in each of the study participants before and immediately after supragingival polishing procedures. Viable bacterial counts and selected putative periodontal pathogens (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia/nigrescens, Fusobacterium nucleatum, Parvimonas micra, Campylobacter species) were quantified by microbial culture, and motile morphotypes (spirochetes and motile rods) by phase-contrast microscopy. Results: Statistically significant decreases were detected after supragingival air polishing in total viable counts (84.9% decrease), in P. intermedia/nigrescens, F. nucleatum, Campylobacter species, total proportions of red/orange complex periodontal pathogens (82.3% decrease), and in motile morphotypes (85.3% decrease). No statistically significant subgingival microbiological changes occurred with supragingival prophylaxis paste polishing. Conclusion: Supragingival air polishing of teeth, but not supragingival prophylaxis paste polishing, may serve as a useful therapeutic adjunct to disrupt and help remove pathogenic biofilms in deep periodontal pockets.


Contexte: Le polissage à air supragingival des dents élimine efficacement la plaque dentaire et les taches extrinsèques sur les surfaces coronaires des dents, mais on ignore son incidence sur les agents pathogènes parodontaux spécifiques des biofilms sous-gingivaux adjacents. Cette étude a évalué l'effet microbiologique du polissage à air supragingival sur le microbiote sous-gingival de clients ayant une parodontite sévère. Méthodologie: Quinze sujets d'essai adultes ont obtenu un polissage à air supragingival à base de poudre de bicarbonate de sodium avec la buse du dispositif de polissage à air orienté à un angle de 45° sur les surfaces immédiatement coronaires à l'entrée des poches parodontales. Treize sujets témoins adultes ont obtenu un polissage prophylactique supragingival à pâte effectué au moyen d'une pièce à main à vitesse lente. Des échantillons sous-gingivaux ont été prélevés d'une seule poche parodontale de 5 mm à 7 mm présentant un saignement au sondage chez chacun des participants de l'étude avant et immédiatement après les procédures de polissage supragingival. Le nombre de bactéries viables et certains pathogènes parodontaux putatifs (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella intermedia/nigrescens, Fusobacterium nucleatum, Parvimonas micra, espèces de Campylobacter) ont été quantifiés par culture microbienne, et les morphotypes mobiles (spirochètes et bâtonnets mobiles) par microscopie à contraste de phase. Résultats: Des réductions statistiquement significatives ont été décelées après le polissage à air supragingival dans le compte total de bactéries viables (diminution de 84,9 %), de P. intermedia/nigrescens, F. nucleatum et des espèces de Campylobacter, dans les proportions totales de pathogènes parodontaux du complexe rouge/orange (diminution de 82,3 %) et dans les morphotypes mobiles (diminution de 85,3 %). Aucun changement microbiologique sous-gingival statistiquement considérable n'a eu lieu avec le polissage prophylactique supragingival à pâte. Conclusion: Le polissage à air supragingival des dents, mais pas le polissage prophylactique supragingival à pâte, peut servir à titre de complément thérapeutique utile pour perturber et aider à éliminer les biofilms pathogènes dans les poches parodontales profondes.


Assuntos
Campylobacter , Placa Dentária , Microbiota , Periodontite , Adulto , Humanos , Bolsa Periodontal/microbiologia , Polimento Dentário , Placa Dentária/terapia , Periodontite/microbiologia
6.
J Periodontol ; 94(9): 1065-1077, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36960491

RESUMO

BACKGROUND: Current periodontal treatment involves instrumentation using hand and/or ultrasonic instruments, which are used either alone or in combination based on patient and clinician preference, with comparable clinical outcomes. This study sought to investigate early and later changes in the subgingival biofilm following periodontal treatment, to identify whether these changes were associated with treatment outcomes, and to investigate whether the biofilm responded differently to hand compared with ultrasonic instruments. METHODS: This was a secondary-outcome analysis of a randomized-controlled trial. Thirty-eight periodontitis patients received full-mouth subgingival instrumentation using hand (n = 20) or ultrasonic instrumentation (n = 18). Subgingival plaque was sampled at baseline and 1, 7, and 90 days following treatment. Bacterial DNA was analyzed using 16S rRNA sequencing. Periodontal clinical parameters were evaluated before and after treatment. RESULTS: Biofilm composition was comparable in both (hand and ultrasonics) treatment groups at all time points (all genera and species; p[adjusted] > 0.05). Large-scale changes were observed within groups across time points. At days 1 and 7, taxonomic diversity and dysbiosis were reduced, with an increase in health-associated genera including Streptococcus and Rothia equating to 30% to 40% of the relative abundance. When reassessed at day 90 a subset of samples reformed a microbiome more comparable with baseline, which was independent of instrumentation choice and residual disease. CONCLUSIONS: Hand and ultrasonic instruments induced comparable impacts on the subgingival plaque microbiome. There were marked early changes in the subgingival biofilm composition, although there was limited evidence that community shifts associated with treatment outcomes.


Assuntos
Placa Dentária , Microbiota , Periodontite , Humanos , RNA Ribossômico 16S/genética , Periodontite/microbiologia , Placa Dentária/terapia , Placa Dentária/microbiologia , Resultado do Tratamento
7.
Clin Oral Investig ; 27(1): 387-398, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36305963

RESUMO

OBJECTIVES: This double-blind, randomized, placebo-controlled clinical trial evaluated the adjuvant effects of Bifidobacterium lactis HN019 on the treatment of plaque-induced generalized gingivitis. MATERIALS AND METHODS: Sixty patients were submitted to professional supragingival scaling and prophylaxis. They were randomly assigned to test (probiotic lozenges containing B. lactis HN019, n = 30) or control (placebo lozenges, n = 30) groups. Lozenges were consumed twice a day for 8 weeks. Bleeding on probing (BoP), Gingival Index (GI), Plaque Index (PI), probing depth (PD), and clinical attachment level (CAL) were evaluated at baseline and after 2 and 8 weeks. Gingival crevicular fluid (GCF) was collected at baseline and at 8 weeks for analysis of the inflammatory mediators IL-1ß, IL-1α, IL-8, MCP-1, and MIP-1ß. Data were statistically analyzed (p < 0.05). RESULTS: After 8 weeks, both groups showed reduction in the percentage of PI, with no significant difference between groups (p = 0.7423). The test group presented a lower percentage of BoP and a higher percentage of sites with GI ≤ 1 when compared with the control group at the end of the study (p < 0.0001). At 8 weeks, the test group had a greater number of patients without generalized gingivitis than the control group (20 and 11 patients, respectively; p < 0.05). The test group presented significantly lower levels of IL-1α, IL-1ß, and MCP-1 in GCF than the control group at the end of the study (p < 0.05). CONCLUSION: The adjunct use of B. lactis HN019 promotes additional clinical and immunological benefits in the treatment of generalized gingivitis. CLINICAL RELEVANCE: B. lactis HN019 can be an efficient and side-effect-free adjunct strategy in the treatment of generalized gingivitis.


Assuntos
Bifidobacterium animalis , Placa Dentária , Gengivite , Placa Aterosclerótica , Humanos , Gengivite/terapia , Raspagem Dentária , Placa Dentária/terapia , Placa Dentária/microbiologia , Administração Oral , Líquido do Sulco Gengival
8.
J Periodontol ; 94(4): 509-518, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35980316

RESUMO

BACKGROUND: Gingivitis is a nonspecific inflammatory lesion in response to the accumulation of oral biofilm and is a necessary precursor to periodontitis. Enhanced oral hygiene practices are necessary to reverse gingivitis and a dentifrice that could provide significant clinical reductions in plaque accumulation and gingival inflammation would be desirable to treat gingivitis and potentially prevent progression to periodontitis. This clinical study aimed to investigate the effect of a novel stannous fluoride-containing dentifrice with 2.6% ethylenediamine tetra-acetic acid (EDTA) as an antitartar agent to reduce Plaque Index (PI) and Gingival Index over a 3-month study period. METHODS: This double-blind, randomized controlled clinical study evaluated plaque, gingival inflammation, and sulcular bleeding in patients using either a novel dental gel containing 0.454% stannous fluoride and 2.6% EDTA or a dentifrice with 0.24% sodium fluoride. Sixty subjects participated over a 3-month period. Co-primary endpoints were improvements in PI and Modified Gingival Index (mGI) from baseline values. No professional cleaning was performed during the study period. RESULTS: All subjects in the study demonstrated statistically significant improvements in all measures of oral hygiene over the 3-month study period. Subjects using the novel dental gel showed statistically significantly greater reductions in PI (ΔPI) [(-1.43 ± 0.34; -0.49 ± 0.13) (p < 0.00001)], mGI (ΔmGI) [(-1.11 ± 0.22; -0.16 ± 0.12) (p < 0.00001)], and modified sulcular bleeding index (ΔmSBI) [(-1.15 ± 0.18; -0.20 ± 0.07) (p < 0.00001)]. CONCLUSIONS: The novel dental gel demonstrated significant improvements in clinical parameters associated with gingivitis compared to a commercially available sodium fluoride dentifrice.


Assuntos
Placa Dentária , Dentifrícios , Gengivite , Humanos , Dentifrícios/uso terapêutico , Fluoreto de Sódio/uso terapêutico , Fluoretos de Estanho/uso terapêutico , Ácido Edético , Índice de Placa Dentária , Placa Dentária/terapia , Gengivite/tratamento farmacológico , Método Duplo-Cego , Inflamação/tratamento farmacológico
9.
Oral Health Prev Dent ; 20(1): 501-508, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36448278

RESUMO

PURPOSE: To compare the effectiveness of two varieties of special needs toothbrushes in terms of dental plaque removal and bacterial contamination vs a conventional toothbrush in patients with Down syndrome. MATERIALS AND METHODS: This single-blinded, two-group, randomised clinical trial included 16 patients diagnosed with Down syndrome (age 6-15 years) from various special needs centers located in the Jazan Province of Saudi Arabia. The patients were randomly allocated to two groups based on the type of special needs toothbrush provided (Collis Curve or superfine nano). The plaque and bleeding indices of the patients in both groups were measured at baseline (T0) and both groups were initially given a conventional toothbrush to use for four weeks. After this period, the plaque and bleeding indices were re-evaluated (T1). The patients were instructed to use the special needs toothbrush for 4 weeks, after which the periodontal indices were re-evaluated (T2). Microbial contamination on the bristles of the special needs brushes was evaluated at T2. RESULTS: No notable changes in the mean plaque and bleeding indices were observed between the two groups at each visit; however, statistically significant reductions were noted between visits in both groups (p < 0.05). The CFU scores in cultures from the Collis Curve toothbrush bristles (1411.5 ± 541.1) were higher than those obtained from the superfine nano-toothbrush bristles (1118.3 ± 423.9), but without statistically significant differences. CONCLUSION: The findings indicate that the use of special needs toothbrushes can statistically significantly improve the gingival health status in individuals with Down syndrome in terms of both resolution of periodontal inflammation and reduction of plaque accumulation.


Assuntos
Placa Dentária , Síndrome de Down , Humanos , Criança , Adolescente , Placa Dentária/terapia , Síndrome de Down/complicações , Escovação Dentária , Índice Periodontal , Gengiva
10.
Clin Exp Dent Res ; 8(5): 1249-1258, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35856483

RESUMO

OBJECTIVES: In our research, we evaluated the effect of coconut and sesame oils using the microneedling technique on gingival inflammation and plaque accumulation among patients with gingivitis by creating microholes in the gingiva to facilitate the concentration and entrance of the oils through gingival tissues. MATERIALS AND METHODS: Twenty-four patients with clinically diagnosed plaque-induced gingivitis were selected from Vision dental hospital, Riyadh, KSA, and assigned to one of three groups randomly; group A consisted of eight participants who were treated with dermapen and topical coconut oil, group B had eight participants who were treated with dermapen and topical sesame oil, and group C involved eight patients who received periodontal mechanical treatment only. Postintervention gingival status and plaque status for all participants were assessed using a modified average gingival index and a plaque index at Weeks 1, 2, and 4. RESULTS: Groups A and B experienced highly significant reductions in gingival indices, while group C showed reduced scores but was not significantly notable. On the contrary, the three studied groups exhibited no significant difference in the reduction of plaque indices when compared altogether. CONCLUSION: Our study demonstrated an effective novel technique that revealed a noticeable improvement in gingival status and a reduction in the average gingival index and plaque index.


Assuntos
Placa Dentária , Gengivite , Óleo de Coco/uso terapêutico , Cocos , Placa Dentária/terapia , Gengivite/terapia , Humanos , Inflamação , Óleo de Gergelim/uso terapêutico
11.
BMC Oral Health ; 22(1): 259, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35761257

RESUMO

BACKGROUND: As the need for care increases with higher age, so does the need for assistance with oral hygiene. A recent study analyzed the clinical effectiveness of oral hygiene assistance provided by caregivers. The current secondary analysis of this study aimed to assess pleasant and unpleasant perceptions of patients while being brushed and to investigate whether these perceptions depend on the qualification of the person brushing and the type of toothbrush used (manual vs. powered). METHODS: First, a qualitative study was conducted. This aimed at developing the questionnaire. Items were extracted on the basis of qualitative interviews with a sample of 6. A delphi process ensured the content validity of the final instrument. The main study comprised 39 periodontitis patients with reduced oral hygiene capability randomized to one of four groups: brushing carried out by trained laypeople or dental professionals, each using a manual or powered toothbrush at three different time points during anti-infective periodontal therapy. Patient perceptions of the third-party toothbrushing were assessed immediately after brushing. RESULTS: Patients reported mainly positive feelings regarding being brushed by a third person and the interaction with this person during brushing. Neither the professional background of the brushing person nor the type of brush had a significant influence on pleasant and unpleasant perceptions (all F < 3.30, all p > 0.07, all η2 < 0.10). CONCLUSIONS: Patient perceptions of third-party toothbrushing are mainly positive regarding wellbeing and interactions with the toothbrushing person, and do not depend on the qualification of the brushing person or the toothbrush used (manual versus powered). Trial registration https://www.germanctr.de , No. DRKS00018779 (04/11/2019).


Assuntos
Placa Dentária , Escovação Dentária , Placa Dentária/terapia , Índice de Placa Dentária , Desenho de Equipamento , Humanos , Assistência Centrada no Paciente , Método Simples-Cego
12.
Clin Exp Dent Res ; 8(4): 849-857, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35445570

RESUMO

OBJECTIVES: This exploratory study investigated plaque removal with a prototype constant, low rotation speed Power Toothbrush (PTB) with two brushing actions: "Gumline" (head rotates in the horizontal axis) and "Interdental" (head rotates in the vertical axis). Gumline alone and "Combined" (Gumline + Interdental) modes were compared with a Reference PTB and a Reference Manual Toothbrush (MTB) after one brushing. MATERIALS AND METHODS: Thirty-nine participants were randomized to use each toothbrush once either in the sequence (A) Prototype PTB (in Gumline then Combined mode), (B) reference MTB, and (C) reference PTB or the sequence BAC. There was a minimum 3-day washout between the use of each toothbrush. Plaque removal was measured using the Rustogi Modified Navy Dental Plaque Index (RMNPI) with change from baseline investigated using an analysis of covariance model. RMNPI scores were calculated on a "whole mouth" basis and along the gingival margin and at proximal sites only. RESULTS: For the primary efficacy variable, a significant difference was found in favor of the prototype PTB in gumline mode versus the reference MTB for whole mouth plaque score (difference: -0.06; standard error: 0.014; 95% confidence interval [CI] -0.09 to -0.04; p < .0001). Similar significant differences were found in gingival margin and proximal areas (p < .0001). The prototype PTB in gumline mode removed significantly less plaque than the prototype PTB in combined mode and the reference PTB (p < .0001; whole mouth/gingival/proximal areas). The prototype PTB in combined mode removed significantly more plaque than the reference MTB (p < .0001; whole mouth/gingival/proximal areas) and the reference PTB for whole mouth (p = .0214) and gingival margin areas (p = .0010). The reference PTB also removed significantly more plaque than the reference MTB (p < .0001; whole mouth/gingival/proximal areas). All brushes were generally well-tolerated. CONCLUSION: The prototype PTB design, providing two distinct cleaning modalities, can effectively remove plaque to a significantly higher degree than an MTB and a marketed PTB, depending on mode.


Assuntos
Placa Dentária/terapia , Gengivite/prevenção & controle , Escovação Dentária/instrumentação , Placa Dentária/prevenção & controle , Índice de Placa Dentária , Humanos , Método Simples-Cego
13.
Clin Oral Investig ; 26(7): 4987-4994, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35355140

RESUMO

OBJECTIVES: This study aimed to investigate the periodontal condition when patients became self-responsible for the continuation of periodontal care, after non-surgical periodontal therapy and 2 years of Supportive Periodontal Therapy (SPT). MATERIALS AND METHODS: Fifty-seven patients completed a previous 2-year SPT study and were afterward advised to seek for dental assistance for maintenance care. After 4.2 ± 0.45 years of self-responsibility for periodontal care (SRPC), 27 patients could be re-examined of which 9 patients had followed the advice to turn to a dental professional for SPT care. Visible Plaque (VPI), Gingival Bleeding (GBI), Periodontal Probing Depth (PPD), Bleeding on probing (BOP), and Clinical Attachment Loss (CAL) were obtained from SPT study: before and after non-surgical treatment, and after 2 years of SPT. The same parameters were reassessed for the present study. General linear models for repeated measures were used for data analysis. RESULTS: At the end of the SRPC period, mean GBI, BOP, and PPD values (43.5%, 55.7%, 2.76 mm, respectively) were back to pre-treatment, whereas VPI (64.3%) and CAL (3.76 mm) became significantly higher. The percentage of sites with PPD ≥5 mm as well as sites with CAL ≥4 or ≥5 mm also returned to pre-treatment values. However, the percentage of sites with PPD ≥4 mm was still significantly lower compared to pre-treatment values but higher than after 2 years of SPT. CONCLUSIONS: Self-responsibility for the continuation of periodontal care after professional treatment should be avoided. CLINICAL RELEVANCE: Clinicians and specialists must be conscious of making all efforts to maintain the patient's frequent recalls.


Assuntos
Placa Dentária , Doenças Periodontais , Placa Dentária/terapia , Seguimentos , Humanos , Perda da Inserção Periodontal
14.
Indian J Dent Res ; 33(4): 445-451, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37006013

RESUMO

Objective: Chewable toothbrushes (CT) are considered an effective tool for dental plaque removal; however, their effectiveness is still uncertain compared to Manual toothbrushes (MT). Aim: To evaluate the effectiveness of CT compared to MT in dental plaque removal. Methods: Studies comparing the efficiency of CT and MT in dental plaque removal measured by Turesky Modification of Quigley-Hein Plaque Index (TMQHI), Quigley-Hein Plaque Index (QHI), or Silness Loe Plaque Index (SLPI) were identified in PubMed, Medline Web of Science, Google Scholar, and the CENTRAL. Results and effect sizes estimate are presented as mean difference, and subgroup analysis is presented separately for non-randomised interventional studies and randomised intervention studies. Risk of bias was assessed using the Cochrane risk of bias tool (ROBINS-I and ROB2 tool). Results: A total of 10 studies were included in the systematic review, whereas six out of 10 studies were included in the meta-analysis. Both CT and MT were effective in plaque reduction over time when compared individually using the TMQHI and SLPI scores. The overall pooled summary showed no difference in CT and MT's dental plaque removal ability when measured using the TMQHI score. Similarly, there was no difference in CT and MT's dental plaque removal ability when measured using the SLPI score. Conclusion: There is no significant difference in CT and MT's plaque removal ability. Therefore, CT should only be recommended for children and individuals with a disability or manual dexterity. Objective: Chewable toothbrushes (CT) are considered an effective tool for dental plaque removal.


Assuntos
Placa Dentária , Gengivite , Criança , Humanos , Dispositivos para o Cuidado Bucal Domiciliar , Placa Dentária/terapia , Escovação Dentária , Índice de Placa Dentária , Desenho de Equipamento
15.
J Vet Dent ; 39(1): 9-20, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34866484

RESUMO

This study was designed to investigate the effects of chlorhexidine 0.12%, TrisEDTA (tromethamine ethylenediamintetraacetic acid), and a combination of chlorhexidine 0.12% and TrisEDTA on an in vitro plaque biofilm model comprised of three bacterial species commonly found in canine subgingival plaque. Porphyromonas gulae, Actinomyces canis, and Neisseria canis were grown in a biofilm on polished hydroxyapatite coated titanium alloy pucks for 72 h prior to exposure to one of four test solutions: TrisEDTA, chlorhexidine 0.12%, a combination of TrisEDTA and chlorhexidine 0.12%, or sterile deionized water as a control. Following exposure to the test solution, a sample was collected of the biofilm either immediately or following 24 h of additional incubation in a broth medium. Lower numbers of CFU/mL of Porphyromonas gulae resulted when the biofilm was treated with a solution of chlorhexidine 0.12% and TrisEDTA compared to with chlorhexidine 0.12% alone, TrisEDTA alone, or the control and so this solution can be said to be synergistic against Porphyromonas gulae in this controlled in vitro model. Greater reductions in the numbers of CFU/mL of Actinomyces canis and Neisseria canis resulted from treatment with chlorhexidine 0.12% alone than if treated with the combination of TrisEDTA and chlorhexidine 0.12%. When treated biofilm samples were allowed 24 h of additional growth in fresh media, greater variance resulted and this variance highlights the complex dynamics involved in bacterial growth within a biofilm.


Assuntos
Placa Dentária , Doenças do Cão , Actinomycetaceae , Animais , Biofilmes , Clorexidina/farmacologia , Placa Dentária/microbiologia , Placa Dentária/terapia , Placa Dentária/veterinária , Doenças do Cão/tratamento farmacológico , Cães , Neisseria , Porphyromonas
16.
J Periodontol ; 93(2): 218-228, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34048073

RESUMO

BACKGROUND: The aim of this clinical trial was to evaluate the effect of a periodontal health education session (PHES), which included education on the pathogenesis and consequences of periodontal diseases on oral hygiene motivation in patients with gingivitis. METHODS: A randomized controlled clinical trial was conducted on 50 (26 females and 24 males) patients with gingivitis who underwent periodontal treatment. Subjects were randomly allocated into the PHES group (experimental group) and standard oral hygiene education group (control group). The Rustogi Modified Navy Plaque Index (RMNPI) and Papillary Bleeding Index (PBI) were used to evaluate oral hygiene at baseline and were repeated after 1, 3, and 6 months. Knowledge about periodontal disease was measured and the participants' motivation was determined using the Oral Hygiene Motivation Scale. RESULTS: Although baseline knowledge levels and motivation scores were not different between the groups, following the educational motivational interviewing (MI) session, levels were higher in the experimental compared with the control group. The subjects' RMNPI and PBI scores at the 1-, 3-, and 6- month re-examinations were statistically higher in the control group than the experimental group. Furthermore, the level of knowledge and intrinsic and total motivation scores were moderately positively correlated with a reduction in clinical indices at 6 months compared with baseline. CONCLUSIONS: The results of this study indicated that increased knowledge and awareness about periodontal diseases and its consequences, including systemic effects, via educational MI session increased intrinsic motivation and improved oral hygiene of patients with gingivitis, especially regarding interproximal surfaces.


Assuntos
Placa Dentária , Gengivite , Doenças Periodontais , Placa Dentária/terapia , Índice de Placa Dentária , Feminino , Gengivite/terapia , Educação em Saúde , Humanos , Masculino , Higiene Bucal , Escovação Dentária
17.
J Evid Based Dent Pract ; 21(2): 101548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34391550

RESUMO

OBJECTIVE: This systematic review aimed to evaluate the efficacy of interproximal plaque scores and gingival inflammation reduction of different toothbrush bristle stiffness and end-shape. METHODS: Randomized clinical trials evaluating the effect of different toothbrushes on interproximal plaque/gingivitis reduction, with a minimum follow-up of 1 week. MEDLINE-PubMed, Scopus and Embase were searched. Soft tapered-tip bristle toothbrushes were compared to soft end-rounded, medium (any end-shape), or hard (any end-shape) bristle toothbrushes. Two meta-analyses were performed for plaque and gingivitis reduction. For plaque index (PI) and gingival index (GI), a standard mean difference (SMD) and mean difference between baseline and 4 weeks were calculated, respectively. In all analyses, random effect models were used. RESULTS: Nine studies were included. All included studies demonstrated statistically significant improvement, in at least one parameter, in favor of the tapered-tip bristle toothbrush compared to the end-rounded bristle toothbrush. When analyzing toothbrush stiffness, medium and hard toothbrushes presented significantly higher improvement when compared to soft toothbrushes in all parameters. In the meta-analyses, groups that used soft tapered-tip bristle toothbrushes demonstrated significant greater reductions in PI (SMD -2.64; 95% CI: -4.26 - -1.01) and in GI (MD -0.14; 95% CI: -0.18 - -0.10) when compared to soft end-rounded bristle toothbrushes. CONCLUSION: It is concluded that, when considering interproximal surfaces, better results may be expected for tapered-tip bristle toothbrushes when compared to end-rounded bristles toothbrushes. Additionally, better results may be expected in medium or hard toothbrushes, regardless of the bristle end-shape, in non-interproximal cleaners.


Assuntos
Placa Dentária , Gengivite , Placa Dentária/terapia , Índice de Placa Dentária , Gengivite/prevenção & controle , Humanos , Índice Periodontal , Escovação Dentária
19.
Angle Orthod ; 90(6): 844-850, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33378520

RESUMO

OBJECTIVE: To determine if an adjunct proteolytic pre-rinse along with contemporary methods of dental cleaning may more effectively remove visual plaque in subjects with fixed orthodontic appliances. MATERIALS AND METHODS: Forty-three orthodontic subjects, ages 10 to 25, completed this single site, double-blind, crossover clinical trial. Subjects randomly received bromelain enzyme or a powdered-sugar placebo pre-rinse, followed by manual tooth brushing and use of a Waterpik. Subjects received the alternate pre-rinse during the subsequent visit. Baseline and residual plaque accumulation were recorded via disclosing tablet and digital photography. A single, blinded examiner scored visual plaque scores from randomized photographs. Treatment effects on composite plaque score were evaluated using repeated-measures analysis of variance. A 5% significance level was used for all tests. RESULTS: No significant differences in plaque scores were noted at baseline or post-rinse between the enzyme and placebo. The changes from baseline to post-rinse (P = .190), post-brushing (P = .764), and post-Waterpik (P = .882) were not significantly different between interventions. Significant reduction in plaque scores were observed in both arms of the study after brushing (P < .01) and waterjet use (P < .01). Neither age (P = .220) nor gender (P = .449) impacted plaque scores. CONCLUSIONS: Use of a bromelain enzyme pre-rinse alone did not significantly enhance plaque removal. A significant reduction in retained plaque was observed with the application of brushing and or Waterpik.


Assuntos
Placa Dentária , Escovação Dentária , Adolescente , Adulto , Criança , Placa Dentária/terapia , Índice de Placa Dentária , Método Duplo-Cego , Humanos , Aparelhos Ortodônticos Fixos , Método Simples-Cego , Adulto Jovem
20.
Acta odontol. latinoam ; 33(3): 174-180, Dec. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1278201

RESUMO

ABSTRACT The aim of the present examiner-blind randomized controlled clinical study was to compare the efficacy two soft-bristle toothbrushes in terms of plaque removal. Seventy volunteers were randomly allocated to Group A (tapered-tip toothbrush) or Group B (end-rounded toothbrush). At baseline appointment (Day 0), volunteers underwent plaque examination using the Improved Plaque Identification Index. Under supervision, they brushed their teeth for 1 minute with their assigned toothbrushes and the plaque examination was repeated. Volunteers continued the oral hygiene regimen (assigned toothbrush and a regular dentifrice provided by the researchers) for 7 days. The experimental procedures of Day 0 were then repeated. Separate statistical analyses were performed for mean percent reduction of plaque in the whole-mouth, interproximal and gumline scores at both times, usingMann-Whitney test, p<0.05. After a single toothbrushing, on Day 0, mean percent plaque was significantly reduced in both groups (p<0.05), with statistically greater reductions of whole-mouth (21.39±12.44 vs. 11.40±11.17), gumline (6.32±7.37 vs. 2.89±4.57) and interproximal (10.82±10.49 vs. 5.21±7.68) for Group A as compared to Group B. However, on day 7, no significant difference was observed between groups for whole-mouth (29.94±20.91 vs. 26.58±18.64), gymline (14.04±18.82 vs. 13.78±17.63) and interproximal surfaces (26.41±22.77vs. 23.12±20.98) (p>0.05). In conclusion, on Day 0, Group A presented higher efficacy in supragingival plaque removal than Group B, as reflected by whole-mouth, gumline and interproximal plaque scores.


RESUMO O objetivo desse ensaio clínico, examinador-cego, randomizado e controle foi de comparadas a eficácia de duas escovas de cerdas macias em relagäo ao controle de placa. Setenta vo-luntários foram randomicamente alocados para Grupo A (es-cova com ponta cónica) ou Grupo B (escova com ponta arredondada). Na consulta inicial (dia 0), voluntarios receberam exame de placa utilizando o Índice de identificagäo de placa melhorado. Sob supervisäo, eles escovaram seus dentes por 1 minuto com as escovas designadas e o exame de placa foi repetido. Voluntarios continuaram seu regime de higiene oral (escova dental alocada e dentifrício comum fornecidos pelos pesquisadores) durante 7 dias. Os procedimentos da consulta inicial foram novamente repetidos. Análises estatísticas distintas foram realizadas para percentual de redugäo média de placa para os escores de boca toda, interproximal e linha gengi-val em ambos os momentos, utilizando teste de Mann-Whitney, p<0,05. Após único uso da escova, no dia 0, o percentual de redugäo média de placa foi significativamente reduzido em ambos os grupos (p<0,05), com reduções significativas para boca toda (21,39±12,44 vs. 11,40±11,17), linha gengival (6,32±7,37 vs. 2,89±4,57) e interproximal (10,82±10,49 vs. 5,21±7,68) no Grupo A quando comparada com o Grupo B. Entretanto, no dia 7, nenhuma diferenga significativa foi observada entre os grupos para boca toda (29,94±20,91 vs. 26,58±18,64), linha gengival (14,04±18,82 vs. 13,78±17,63) e interproximal (26,41±22,77 vs. 23,12±20,98) (p>0,05). Em conclusäo, no dia 0, a escova do Grupo A apresentou eficácia superior na remo-gäo de placa suprageng ival quando comparada com a escova do Grupo B, como demonstrado nos escores de placa de boca toda, linha gengival e interproximal.


Assuntos
Humanos , Escovação Dentária/instrumentação , Placa Dentária/terapia , Gengivite/terapia , Higiene Bucal , Método Simples-Cego , Índice de Placa Dentária , Resultado do Tratamento , Biofilmes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...